24 Hour Timer Switch, 24h Timer Switch ATP1006-3

24 Hour Timer Switch, 24h Timer Switch ATP1006-3 (hereinafter referred to as “time switch”) 
is mainly used as time control elements in the circuit with AC frequency of 50Hz,
rated control power voltage of 220V at most and DC current of 3A at most, 
such as being used to regularly control switch-on and off of street lamps, 
advertising light boxes and other equipments, 
the product may be used to adjust the switch-on and off time everyday according to the latitude. 
The product complies with the requirements of Standard GB 14048.5 and IEC 60947-5-1. 
2. Model and Its Meaning: ATP1006-3 
3. Normal Operating Condition and Installation Condition 
3.1 Ambient air humidity: -5℃~+40℃, and the average temperature is no more than +35℃ in 24h.
3.2 Altitude: no more than 2,000m. 
3.3 Humidity: the relative air humidity of the installation site shall be no more than 50% when the 
maximum temperature is +40℃, while it can be higher under lower temperature. Special measures 
shall be taken for the condensation occasionally formed due to temperature change. 
3.4 Pollution level: 3. 
3.5 In the medium with explosion hazard and no gas that is enough to corrode metal and destroy 
the insulation and the place shall not have severe conductive dust. 
3.6 In the place where is provided with anti-snow and anti-rain equipment but not be full of water steam. 
3.7 In the place without significant shake, shock and vibration. 
3.8 Installation class: II. 
3.9 Transport and Storage Conditions: -25℃ to +55℃. 
3.10 Power voltage change scope: 85%~110% rated operating voltage. 
3.11 Protection grade: IP20. 
https://www.amazon.com/dp/B01LWOTO0H

ATP1006-6 time switch with 2 outputs



ATP1006-6 time switch with 2 outputs
Is applicable for regularly controlling switch-on and off of circuit, this product can control 2 channels output.
Each channel can be set up 7 groups time, time range for 1 second – 1 week.
2. Main Technical Parameters
2.1 Rated control power voltage: 220VAC.
2.2 Conventional thermal current: Ith 10A.
2.3 Category of the control circuit: AC-1.
2.4 Rated working current (Ie): AC-1 220V 10A.
2.5 Timing error: ≤1s/d.
2.6 control load:2 loads.
2.7 Set number of time: 7 groups.
2.8 Time control scope: 1sec~168h.
2.9 Mechanical life: ≥30,000 times.
2.10 Electric endurance: ≥10,000 times.
2.11 Installation method: Device installed, guide tracked.